Class Cabinet - メーカー・企業と製品の一覧 | イプロス

Class Cabinetの製品一覧

1~2 件を表示 / 全 2 件

表示件数

Biohazard Safety Class 2 Cabinet Type B2

The design features a tilt of about 10 degrees on the front glass, allowing for operation in a natural posture! It is a fully exhaust type.

■Features 〇All fresh type 〇The front glass is tilted at approximately 10 degrees, allowing for operation in a natural posture. 〇The work surface is made of all stainless steel, excellent in chemical resistance and durability. 〇The differential pressure gauge allows monitoring of the exhaust HEPA filter's condition. 〇The automatic shut-off time for the sterilization lamp can be set (30 minutes/60 minutes/90 minutes/120 minutes/240 minutes/continuous). 〇Equipped with a standard operation cumulative meter, which can serve as a guideline for HEPA filter replacement timing. 〇Inspections and maintenance of HEPA filters are conducted by certified inspectors from JACA field inspection technicians, ensuring peace of mind. 〇The sterilization lamp can only be turned on when the sliding glass is closed, ensuring a safety-conscious system. It includes a function to prevent simultaneous lighting of the illumination and sterilization lamp. 〇Standard equipment includes an outlet in the work area, gas piping, and vacuum piping.

  • Clean Room
  • Class Cabinet

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Biohazard Safety Class II Cabinet Type A2 Series

The design features a tilt of about 10 degrees on the front glass, allowing for operation in a natural posture!

■Features ● The form has an inclination of about 10 degrees on the front glass, allowing for operation in a natural posture. ● Wind speed display is standard equipment. It allows monitoring of the blowing wind speed and inflow wind speed. Ideal for monitoring airflow balance. ● The automatic shut-off time for the sterilization lamp can be set (30 minutes / 60 minutes / 90 minutes / 120 minutes / 240 minutes / continuous). ● An operating cumulative counter is standard equipment, which can serve as a guideline for when to replace the HEPA filter. ● Inspections and maintenance of HEPA filters are conducted by certified inspectors from JACA field inspection technicians, ensuring peace of mind. ● The sterilization lamp can only be turned on when the sliding glass is closed. This is a safety-conscious system, equipped with a function to prevent simultaneous lighting of the illumination and sterilization lamp. ● Standard equipment includes an outlet in the work area, gas piping, and vacuum piping.

  • Clean Room
  • Class Cabinet

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録